Threat Advisory

Netgate pfSense CE through 2.9.0 contains a newline injection vulnerability in services_pppoe_edit.php that allows privileged users to inject mpd.secret (CVE-2026-111219)

MEDIUM CVSS 6.6 injection Published October 15, 2026

What happened

Netgate pfSense Community Edition (CE) versions 2.9.0 and earlier contain a newline injection vulnerability in the <code>services_pppoe_edit.php</code> component. This vulnerability permits privileged users to inject malicious entries into the <code>mpd.secret</code> configuration by submitting unvalidated username POST fields. An attacker with the PPPoE Server Edit privilege can exploit this flaw by adding a line beginning with a ‘!’, which causes the <code>mpd5</code> process to execute commands with root privileges when a PPPoE client authenticates. The vulnerability is reachable remotely over a network and does not require user interaction, although it necessitates that the attacker already possesses high privileges on the system. The flaw’s CVSS score is 6.6, indicating a medium severity risk, primarily due to its privilege escalation potential, which could lead to remote code execution under specific conditions.

Who is affected

Any organisation running pfSense CE versions 2.9.0 or earlier and permitting external network access to the PPPoE service may be affected. The vulnerability relies on a known privilege level within the system, meaning that only users with the ability to alter PPPoE server settings can exploit it. Systems where access is restricted through network segmentation, strict access controls, or not exposed directly to untrusted networks are less likely to be impacted. Nonetheless, the potential for remote exploitation warrants caution and raises the importance of proper network security measures for affected deployments.

Recommended actions

  1. Restrict network access to the PPPoE service to trusted sources, ideally within protected network segments.
  2. Implement strong access controls to prevent privilege escalation within the system, ensuring only trusted administrators can modify PPPoE configurations.
  3. Monitor for suspicious activity related to PPPoE server management and privilege escalation attempts.
  4. Apply any available updates or security patches issued by the vendor for affected versions once they are released.
  5. Review and verify network segmentation and firewall rules to limit exposure to this service from untrusted networks.

Affected

Vendors: Netgate

Products: pfSense CE

Source

NVD — Read article

Need help applying this fix?

EXEO can assess your exposure and remediate it for you.

Talk to Managed Security Services or see Argos threat intelligence

At a glance

SeverityMedium
CVSS6.6
CVECVE-2026-111219
PublishedOctober 15, 2026
VendorNetgate
ProductspfSense CE
Regionsglobal
Exeo Logo White Transparent

Get in touch

We respond within 1 hour on weekdays

This channel is not monitored by HR. For a job application or an internship, please visit our Join Us page.