What happened
CVE-2023-25914 is a path traversal vulnerability in the Danfoss AK-SM 800A Series. Due to improper restriction, an authenticated attacker with a low-privileged account can retrieve and read system files from the underlying server through the XML interface. The information obtained can lead to full system compromise. The attack is reachable over a network and requires no action from any user.
The vulnerability is rated high, with a CVSS base score of 8.8. It is actively exploited in the wild and is listed in CISA’s Known Exploited Vulnerabilities catalogue. The weakness is classified as CWE-22. The patch status is not stated in the available facts.
Who is affected
Organisations running Danfoss AK-SM 800A Series versions earlier than 3.3 are affected; the verified affected-version scope is AK-SM800A: < 3.3. The vulnerable component is the product’s XML interface. Exploitation requires a low-privileged account, but does not require user interaction.
Recommended actions
- Restrict network exposure of the XML interface and prevent direct access to the exposed service from untrusted networks.
- Segment affected deployments so that access to the service is limited to necessary network paths.
- Apply access controls in front of the service to restrict which accounts and network sources can reach it.
- Check the vendor advisory for fixed versions and apply the vendor’s mitigations or updates. The available facts do not state patch status or identify fixed versions.